online_scour_hec18:  Calculation of bridge scour using the HEC-18 formula   


Fr1 = v1/(g y1)1/2

ys /y1 = 2 K1 K2 K3 (a / y1)0.65 Fr10.43

[ SI Units (metric):  ys, y1, a, and L in m ]
[ U.S. Customary Units:  ys, y1, a, and L in ft ]
[ Fr = Froude number; g = gravitational acceleration ]


Evaluating Scour at Bridges,
FHWA Hydraulic Engineering Circular No. 18,
Fifth Edition, 2012.

INPUT DATA:      [Description]     [Sample Input]


Flow depth y1 :      


Flow velocity v1 :      


Pier width a :      


Pier length L :      


Angle of attack θ of the flow (degrees):      


Pier nose shape:      

Bed condition:      


System of units:  SI units (metric)

Pier nose shape:  Square nose

Bed condition:  Clear-water scour

  Scour depth ys :     

Press button to
or recalculate

  Your request was processed at  04:45:24 am on March 22nd, 2018   [ 180322  04:45:24 ].

Thank you for running   online_scour_hec18   Please call again.   [171021]